SwOS is an operating system designed specifically for administration of MikroTik switch products. SwOS is configurable from your web browser. It gives you all the basic functionality for a managed switch, plus more: allows to manage port-to-port forwarding, broadcast storm control, apply MAC filter, configure VLANs, mirror traffic, apply. Oct 05, 2020 Mikrotik winbox for mac os splynx. Winbox v3.21 (feb 2020) for macos 64 bit catalina. This is not a signed package, you will have to right click the application and choose open the first time. If upgrading, you can backup your saved managed sessions from tools export but be sure to save them to a location outside of the application because.
- 5System
- 13VLAN and VLANs
- 17ACL Tab
Summary
SwOS is an operating system designed specifically for administration of MikroTik switch products.
SwOS is configurable from your web browser. It gives you all the basic functionality for a managed switch, plus more: allows to manage port-to-port forwarding, broadcast storm control, apply MAC filter, configure VLANs, mirror traffic, apply bandwidth limitation and even adjust some MAC and IP header fields.
Warning: Each RouterBOARD switch series device has its own firmware which cannot be installed on other series models! CSS326-24G-2S+ supports SwOS v2.0 and newer.
CSS326 features
Features | Description |
---|---|
Forwarding |
|
Spanning Tree Protocol |
|
Link Aggregation |
|
Multicast Forwarding |
|
Mirroring |
|
VLAN |
|
Security |
|
Quality of Service (QoS) |
|
Access Control List |
|
Connecting to the Switch
Open your web browser and enter IP address of your Switch (192.168.88.1 by default) and login screen will appear.
SwOS default IP address:192.168.88.1, user name:admin and there is no password.
Note: MikroTik Neighbor Discovery protocol tools can be used to discover IP address of Mikrotik switch. Manual:IP/Neighbor_discovery. Currently LLDP is not supported.
Interface Overview
CSS326-24G-2S+ SwOS interface menu consists of multiple tabs: Link, SFP, SFP Status, Port Isolation, LAG, Forwarding, Stats, Errors, Histogram, VLAN, VLANs, Static Hosts, Hosts, SNMP, ACL, System and Upgrade.
Description of buttons in SwOS configuration tool:
- Append - add new item to the end of the list
- Apply All - applies current configuration changes
- Cut - removes item from the list
- Clear - resets properties of the item
- Discard Changes - removes unsaved configuration
- Insert - add new item to the list (places it before current item)
- Sort - sort VLAN table by VLAN-IDs; sort host table by MAC addresses
- Change Password - changes password of the switch
- Logout - logout from current Switch
- Reboot - reboot the switch
- Reset Configuration - reset configuration back to factory defaults
- Choose File - browse for upgrade or backup file
- Upgrade - upgrade firmware of the Switch
- Restore Backup - restore Switch using selected backup file
- Save Backup - generate and download backup file from the Switch
System
System Tab performs the following functions:
- General information about Switch
- Switch management
- Configuration reset
- Backup and restore configuration
Note: SwOS uses a simple algorithm to ensure TCP/IP communication - it just replies to the same IP and MAC address packet came from. This way there is no need for Default Gateway on the device itself.
Property | Description |
---|---|
Address Acquisition | Specify which address acquisition method to use:
|
Static IP Address | IP address of the switch in case of Address Acquisition is set as DHCP with fallback or static |
Identity | Name of the switch (for Mikrotik Neighbor Discovery protocol) |
Allow From | IP address from which the switch is accessible. Default value is '0.0.0.0/0' - any address |
Allow From Ports | List of switch ports from which it is accessible |
Allow From VLAN | VLAN ID from which the switch is accessible (VLAN Mode on ingress port must be other than disabled in order to connect) |
Watchdog | Enable or disable system Watchdog. It will reset CPU of the switch in case of fault condition |
Independent VLAN Lookup | Enable or disable independent VLAN lookup in the Host table for packet forwarding |
IGMP Snooping | Enable or disable IGMP Snooping |
Mikrotik Discovery Protocol | Enable or disable Mikrotik Neighbor Discovery protocol |
MAC Address | MAC address of the switch (Read-only) |
Serial Number | Serial number of the switch (Read-only) |
Board Name | MikroTik model name of the switch (Read-only) |
Uptime | Current switch uptime (Read-only) |
DHCP & PPPoE Snooping
Property | Description |
---|---|
Trusted Ports | Group of ports, which allows DHCP or PPPoE servers to provide a requested information. Mainly used to limit unauthorized servers to provide malicious information for users, access ports usually do not configure as trusted |
Add Information Option | Enables or disables DHCP Option-82 information. When enabled, the Option-82 information (Agent Remote ID and Circuit ID) is added for DHCP packets received from untrusted ports. Can be used together with Option-82 capable DHCP server to assign IP addresses and implement policies |
Health
Property | Description |
---|---|
Temperature | Shows PCB temperature in celsius temperature scale (Read-only) |
Password and Backup
Link
Link Tab allows you to:
- Configure Ethernet and SFP+ ports
- Monitor link status of Ethernet and SFP+ ports
Property | Description |
---|---|
Enabled | Enable or disable port |
Name | Editable port name |
Link Status | Current link status (Read-only) |
Auto Negotiation | Enable or disable auto negotiation |
Speed | Specify speed setting of the port (requires auto negotiation to be disabled) |
Full Duplex | Specify duplex mode of the port (requires auto negotiation to be disabled) |
Flow control | Enable or disable 802.3x Flow control |
SFP
SFP tab allows you to monitor status of SFP modules.
Port Isolation
Port Isolation table allows or restricts traffic forwarding between specific ports. By default, all available switch chip ports can communicate with any other port, there is no isolation used. When the checkbox is enabled/ticked you allow to forward traffic from this port towards the ticked port. Below are some port isolation examples.
In some scenarios you might need to isolate a group of devices from other groups. In this example devices on Port1-Port5 are not able to communicate with Port6-Port10 devices, and vice versa. | In some scenarios you might need to forward all traffic to an uplink port while all other ports are isolated from each other. This kind of setup is called Private VLAN configuration. The switch will forward all Ethernet frames only to the uplink Port1, while uplink can reach all other ports | Individual isolated Port1 (e.g. for management purpose), it cannot send or receive traffic from any other port |
Note: It is possible to check/uncheck multiple checkboxes by checking one of them and then dragging horizontally (Click & Drag).
Note: (R)STP will only work properly in Private VLAN setups. In setups with multiple isolated switch groups (R)STP might not properly receive BPDUs and therefore fail to detect network loops.
LAG
CSS326-24G-2S+ supports 802.3ad (LACP) compatible link aggregation as well as static link aggregation to ensure failover and load balancing based on Layer2 and Layer3 hashing.
Up to 16 link aggregation groups with up to 8 ports per a group are supported.
Each individual port can be configured as Passive LACP, Active LACP or a Static LAG port.
Property | Description |
---|---|
Mode(default: passive) | Specify LACP packet exchange mode or Static LAG mode on ports:
|
Property | Description |
---|---|
Group | Specify a Static LAG group |
Trunk(read only) | Represents group number port belongs to. |
Partner(read only) | Represents partner mac-address. |
Forwarding
Forwarding Tab provides advanced forwarding options among switch ports, port locking, port mirroring, bandwidth limit and broadcast storm control features.
Property | Description |
---|---|
Port Lock |
|
Port Mirroring |
|
Broadcast Storm Control |
|
Bandwidth Limit |
|
RSTP
Per port and global RSTP configuration and monitoring is available in the RSTP menu.
Property | Description |
---|---|
Bridge Priority (hex) | RSTP bridge priority for Root Bridge selection |
Port Cost Mode | There are two methods for automatically detecting RSTP port cost depending on link speed.
|
Root Bridge | The priority and MAC address of the selected Root Bridge in the network (Read-only) |
Property | Description |
---|---|
RSTP | Enable or disable STP/RSTP functionality on this port |
Mode | Shows STP/RSTP functionality mode on specific port (Read-only):
|
Role | Shows specific port role (Read-only):
|
Root Path Cost | Shows root path cost for ports that are facing root bridge (Read-only) |
Type |
|
State | Shows each port state (Read-only):
|
Stats, Errors and Histogram
These menus provide detailed information about received and transmitted packets.
Note: Statistics for SFP+ interface are cleared whenever an active SFP+ link is established.
VLAN and VLANs
VLAN configuration for switch ports.
Mikrotik Winbox For Mac Os X
Property | Description |
---|---|
VLAN Mode (disabled | optional | enabled | strict; Default: optional) | VLAN filtering mode, these options are relevant to egress ports (except for strict mode).
|
VLAN Receive (any | only tagged | only untagged; Default: optional) | Ingress traffic filtering based on VLAN tag presence.
|
Default VLAN ID (integer: 1..4095; Default: 1) | VLAN ID which will be assigned on ingress traffic. Only has effect on untagged traffic, it will be ignored for tagged traffic. This parameter is usually used to allocate access ports with specific VLAN. It is also used to untag egress traffic if packet's VLAN ID matches Default VLAN ID. |
Force VLAN ID (integer: yes | no; Default: no) | Assigns the Default VLAN ID value to all ingress traffic (tagged and untagged). Has effect in all VLAN Modes. If port receives tagged traffic and Default VLAN ID is set to 1, then with this parameter the egress traffic will be untagged. |
VLAN membership configuration for switch ports.
Property | Description |
---|---|
VLAN ID (integer: 1..4095; Default: 0) | VLAN ID to which assign ports. |
Port Isolation (yes | no; Default: yes) | Use settings from Port Isolation menu to isolate the defined VLAN to only certain ports. When disabled, the switch will ignore port isolation configuration and forward traffic with the defined VLAN ID only to ports that are checked as members. |
Learning (yes | no; Default: yes) | Enables or disables MAC address learning on the defined VLAN. If disabled, then all learned MAC addresses will appear as they have had been learned from VLAN 1. |
Mirror (yes | no; Default: no) | Enables or disables VLAN based mirroring. When enabled and Mirror To is set in the Forwarding menu, then all traffic from the defined VLAN will be mirrored to the selected port. |
IGMP Snooping (yes | no; Default: no) | Enables or disables IGMP Snooping on the defined VLAN. When enabled, the switch will listen to IGMP Join and Leave requests from the defined VLAN and only forward traffic to ports, which have sent IGMP membership requests from the defined VLAN. When disabled, the switch will flood all VLAN member ports with Multicast traffic. |
Members (ports; Default: none) | Group of ports, which are allowed to forward traffic on the defined VLAN. |
VLAN Configuration Examples
Simple trunk and access port configuration, as well as trunk and hybrid port configuration examples can be found in this article - SWOS/CSS326-VLAN-Example.
Hosts
This table represents dynamically learnt MAC address to port mapping entries. It can contain two kinds of entries: dynamic and static. Dynamic entries get added automatically, this is also called a learning process: when switch receives a packet from certain port, it adds the packet's source MAC address and port it received the packet from to host table, so when a packet comes in with certain destination MAC address it knows to which port it should forward the packet. If the destination MAC address is not present in host table then it forwards the packet to all ports in the group. Dynamic entries take about 5 minutes to time out. CSS326-24G-2S+ supports 16383 host table entries.
Static entries will take over dynamic if dynamic entry with same mac-address already exists. Also by adding a static entry you get access to some more functionality.
Property | Description |
---|---|
Ports | Ports the packet should be forwarded to |
MAC | MAC address |
VLAN ID | VLAN ID |
Drop | Packet with certain MAC address coming from certain ports can be dropped |
Mirror | Packet can be cloned and sent to mirror-target port |
Property | Description |
---|---|
Port | Ports the packet should be forwarded to (Read-only) |
MAC | Learned MAC address (Read-only) |
VLAN ID | Learned VLAN ID (Read-only) |
IGMP Snooping
IGMP Snooping which controls multicast streams and prevents multicast flooding is implemented in SwOS starting from version 2.5. The feature allows a switch to listen in the IGMP conversation between hosts and routers.
Mikrotik For Mac Os 10.10
Enable option under System tab.
Available IGMP snooping data can be found under IGMP tab:
Possibility to enable IGMP Snooping for specific VLAN ID.
Note: IGMP Snooping for VLANs requires enabled 'Independent VLAN Lookup' in the System menu.
SNMP Tab
SwOS supports SNMP v1 and uses IF-MIB, SNMPv2-MIB, BRIDGE-MIB and MIKROTIK-MIB (only for health and SFP diagnostics) for SNMP reporting.
Available SNMP data:
System information
System uptime
Port status
Interface statistics
Host table information
Property | Description |
---|---|
Enabled | Enable or disable SNMP service |
Community | SNMP community name |
Contact Info | Contact information for the NMS |
Location | Location information for the NMS |
ACL Tab
An access control list (ACL) rule table is very powerful tool allowing wire speed packet filtering, forwarding and VLAN tagging based on L2,L3 protocol header field conditions. Each rule contains a conditions part and an action part.
Conditions part parameters
Property | Description |
---|---|
From | Port that packet came in from |
MAC Src | Source MAC address and mask |
MAC Dst | Destination MAC address and mask |
Ethertype | Protocol encapsulated in the payload of an Ethernet Frame |
VLAN | VLAN header presence:
|
VLAN ID | VLAN tag ID |
Priority | Priority in VLAN tag |
IP Src (IP/netmask:port) | Source IPv4 address, netmask and L4 port number |
IP Dst (IP/netmask:port) | Destination IPv4 address, netmask and L4 port number |
Protocol(integer) | IP protocol |
DSCP | IP DSCP field |
Action part parameters
Property | Description |
---|---|
Redirect To | Force new packets destination port |
Mirror | Clones packet and sends it to mirror-target port |
Rate | Limits bandwidth (bps) |
Drop | Drop packet |
Set VLAN ID | Changes the VLAN tag ID, if VLAN tag is present |
Priority | Changes the VLAN tag priority bits, if VLAN tag is present |
Mikrotik L2tp Mac Os X
Reset and Reinstall
CSS326-24G-2S+RM has built-in backup SwOS firmware which can be loaded in case standard firmware breaks or upgrade fails:
- Holding Reset button for few seconds while CSS326-24G-2S+RM is booting resets configuration and loads backup firmware SwOS 2.0p.
- After loading backup firmware SwOS 2.0p it is possible to connect to 192.168.88.1 using web browser and install new SwOS firmware.